Application data, 58ss/dh induced-combustion gas-fired furnaces, Installation guidelines procedures • Read online or download PDF • Carrier 58SS/DH User. Carrier Furnace Model 58SSBC (58SSBC) Parts – Shop online or call Fast shipping. Open 7 days a week. day return policy. Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline.

Author: Brashicage Taukree
Country: Djibouti
Language: English (Spanish)
Genre: Music
Published (Last): 27 September 2009
Pages: 494
PDF File Size: 14.29 Mb
ePub File Size: 18.30 Mb
ISBN: 243-4-69749-277-1
Downloads: 47315
Price: Free* [*Free Regsitration Required]
Uploader: Moogugrel

Do not block openings in front of furnace or on. In some instances, these instructions exceed certain local codes and ordinances, especially those that may not have kept pace with changing construction practices.

Aprilaire – Basic Solenoid Question. The desire to conserve energy. Tub pump air tube came off. It should work as long as the valve is happy enough with the half-wave AC input and will prevent the sparker from being on all the time Trying to hook up tire changer motor to switch.

Seperate the pilot at the molex plug and the wiring going to the furnace install a jumper in the green and yellow holes.

Install furnace as level as possible.

Carrier 58ss gas furnace dead: hold coil?

Check available gas supply to see that it conforms to. Find all posts by neurocutie. Use these procedures in conjunction with your specific furnace installation carirer.

  AMMC 5618 PDF

It looks like the sparker does indeed stay on all the time because of the different circuit design. Find all posts by mbk3. Always comply with minimum fire protection clearances shown on unit rating plate. Portions of the following have been adopted in part.

Originally Posted by furd. They also reflect current conditions found in the field, and conform to existing national standards, and safety codes. As always when troubleshooting the thermostat must be calling for heat. I don’t know what activates the sail switch or where it is located but it seems as if it is not closing to the hold coil.

Carrier 58SS 3SI Gas Furnace Owners Manual

When a furnace is installed so that the supply ducts. If no main burner take a voltage reading at 1 and a ground or common terminal on the 58ws.

I don’t have to diagram in front of me It does add a bridge rectifier, not sure what the point of that is Under all eonditions, 58zs air must be provided to ensure there will be no negative pressure condition.

Find all posts by Skip Do not install directly on carpeting, tile or any combustible material other than wood flooring.

Find all posts by Furd. Replacement air must be provided by means of ducts from the outside to the furnace area or heated.

  ADC0800 DATASHEET PDF

Can water bypass my filter??? Since you have a pretty good grasp of this circuit I’ll go ahead and give you a way to check the valve. The only side effect I can see is that the pilot gas won’t flow til the inducer switches on the hold coil S-2XA Pg 1 Replaces: Originally Posted by nartkram. Nor do I understand what appears to be a jumper across the normally open contacts of the inducer fan motor relay 2D. All fuel-burning furnaces must be supplied with air.

You have to have both sections open for the main flame.

Carrier 58SS Manuals

It looks like it is in there solid Protection Association and American Gas Association. So my understanding now is that the only point of separate pick and hold phases is to allow the xarrier a few seconds to light before the inducer kicks in and creates a draft that would make lighting the pilot harder.

All fuel-burning furnaces must be supplied with air that enters the combustion process and then is vented to the outdoors.